How to select the appropriate surge arrester for high voltage switchgear?

Nov 11, 2026

Leave a message

William Wilson
William Wilson
William is an experienced technician at Jiangsu Perfect Electric. He is skilled in the maintenance of busways and compact substations. His professional skills ensure the safe operation and reliable performance of power distribution systems.

When it comes to safeguarding high voltage switchgear, surge arresters aren’t just a peripheral component—they’re the first line of defense against the transient overvoltages that can cripple critical power infrastructure. As a high voltage switchgear supplier, I’ve seen firsthand how choosing the wrong arrester leads to unplanned downtime, costly repairs, and even safety hazards for operators. Over 15 years in this industry, I’ve worked with industrial plants, utility providers, and renewable energy developers to match surge arresters to specific switchgear systems, and today I’m breaking down the most critical factors to make this selection process clear, not complicated.

First, let’s ground this in context. Whether you’re working with a compact medium voltage (MV) KYN28A-12 Medium Voltage Switchgear for manufacturing facilities or a high voltage (HV) system for transmission grids, the switchgear is the heart of your power distribution network. It controls, protects, and isolates electrical equipment, but it’s vulnerable to two main overvoltage types: internal (from switching operations, such as circuit breaker closures or recloser activations) and external (from lightning strikes on power lines or nearby equipment). A poorly matched surge arrester won’t divert these surges effectively, while an overdesigned unit adds unnecessary cost and bulk to a switchgear setup. That’s why alignment between the arrester’s specs and your switchgear’s parameters is non-negotiable.

The very first step in this process is to fully map your switchgear’s electrical characteristics, starting with its rated system voltage. This is the foundation of all arrester selection, and it’s where many teams slip up by relying on nominal system voltage rather than the actual operating voltage. For example, a KYN28A-12 Medium Voltage Switchgear is rated for 12 kV nominal, but its maximum continuous operating voltage (MCOV) might be 13.8 kV depending on the grid’s regulations in your region. The arrester’s MCOV must equal or exceed this value—if it’s lower, the arrester will age prematurely, especially in areas with stable, high operating voltages that keep the arrester energized 24/7. I’ve seen this mistake cause arresters to fail in as little as two years in tropical regions where grid voltages run consistently 5% above nominal, so double-checking MCOV against your switchgear’s manual is non-negotiable.

Next, you need to account for the location of your switchgear and the threat level it faces. A utility substation located in a lightning-prone region of the US will have vastly different surge requirements than a manufacturing plant in a city where lightning strikes are rare. I always split this into two categories: external surge sources (lightning) and internal surge sources (switching surges within the switchgear itself). For switching surges, which often occur when inductive loads like motors or transformers are connected or disconnected, the arrester’s nominal discharge current (usually 5 kA for MV switchgear) and energy absorption capability are key. For lightning, which can inject currents of 10 kA or more, you’ll need an arrester rated for higher impulse current, often 10 kA or 20 kA, to handle the sudden, massive energy spike without thermal runaway.

As a supplier, we frequently work with customers who don’t account for the physical fit of the surge arrester within their switchgear enclosure, and this is a surprisingly common bottleneck. Take the KYN28A-12 Medium Voltage Switchgear, which has a compact cubicle design with limited space in the busbar compartment. A surge arrester that’s too tall or has a larger base diameter than the designated mounting slot can require a full switchgear redesign, delaying projects by weeks or adding unplanned costs. When selecting an arrester, check the mounting dimensions specified in your switchgear’s technical datasheet: most KYN28A-12 units are designed for arresters with a maximum height of 450 mm and a bolt pattern that fits 100 mm square mounting holes. We now include a dimension checklist for every arrester we quote, to eliminate this back-and-forth for our customers.

Another critical factor is the arrester’s protective ratio, which is the ratio of its residual voltage (the voltage remaining across the arrester during a surge discharge) to the MCOV. A lower protective ratio means the arrester clamps surges to a lower voltage, better protecting sensitive components like insulation in the switchgear’s circuit breakers, transformers, and busbars. For HV switchgear handling critical loads like data centers or medical facilities, a protective ratio of less than 2.5 is ideal—anything higher can leave insulation at risk of breakdown during a large surge. That said, a lower ratio often comes at a higher cost, so it’s a balance between protection needs and budget. I always advise customers to run a quick insulation coordination calculation: if your switchgear’s insulation level is rated for 75 kV, an arrester with a residual voltage of 60 kV (a 2.4 ratio) will provide sufficient protection without overspending.

KYN28A-12 Medium Voltage Switchgear

Regional standards can’t be overlooked here, as they dictate minimum requirements for arrester performance that vary by country. In the US, we follow ANSI/IEEE standards, while in Europe, IEC standards are the norm. For example, IEC 60099-4 defines the requirements for metal oxide surge arresters, which are the standard today (replacing older silicon carbide types) due to their better energy handling and lower residual voltage. For customers in Canada, CSA standards add specific testing requirements for cold climate performance, since surge arresters in temperatures below -30°C need to maintain consistent electrical characteristics without arcing. I once had a customer in northern Alberta try to use an arrester rated for temperate climates for their KYN28A-12 switchgear—within a year, the unit failed due to brittle seal material that cracked in the cold, leading to moisture ingress. That’s when I started including regional standard checklists in our quotes, so customers don’t have to research these rules on their own.

Don’t forget about application-specific use cases, which can drastically narrow down your arrester options. If your switchgear is part of a photovoltaic (PV) farm, for example, it will face different surges from DC side switching and temporary overvoltages from solar arrays operating in low-demand conditions. We developed a custom surge arrester for PV integrated KYN28A-12 Medium Voltage Switchgear that includes additional thermal protection to handle the higher ambient temperatures common in desert installations. For offshore wind applications, where saltwater corrosion is a risk, we offer arrester housings made of fiberglass-reinforced epoxy instead of porcelain, to withstand harsh marine environments. Even for industrial switchgear controlling large motors, we recommend arresters with fast discharge times, as motor switching surges occur in milliseconds and require immediate diversion.

Testing and certification are non-negotiable quality markers, especially for critical infrastructure. I only work with arresters that have third-party certification from bodies like UL, IEC, or CSA, because these tests validate that the unit will perform as advertised under real-world conditions. A certified arrester will have passed impulse current tests, thermal stability tests, and long-term aging tests—something that off-brand, untested units often skip. A few years ago, we had a customer test an uncertified arrester for their switchgear; during a simulated lightning surge, the unit exploded, damaging the busbar cubicle and taking the switchgear offline for three days. The certified alternative cost 15% more upfront but saved them over $50,000 in repairs and downtime. I always tell customers that cutting corners on certification is a false economy that leads to far higher costs later.

Finally, it’s important to plan for long-term maintenance, because even the best surge arrester needs periodic checks to ensure it’s still functioning. Metal oxide arresters degrade over time due to thermal stress, moisture, and surge events, so selecting an arrester with a monitoring option can save you from unexpected failures. Many modern arresters come with a status indicator that changes color when the unit is approaching the end of its life, or even remote monitoring capabilities that send alerts to your maintenance team if the arrester’s leakage current exceeds safe levels. For switchgear systems in remote locations, like rural utility lines or mine sites, remote monitoring is a game-changer—it eliminates the need for manual inspections in hazardous or hard-to-reach areas.

As a high voltage switchgear supplier, our goal is to make this selection process seamless, not overwhelming. Whether you’re equipping a new KYN28A-12 Medium Voltage Switchgear for an automotive plant, upgrading an HV substation, or integrating switchgear into a renewable energy project, we walk you through every step: confirming system voltage and MCOV, assessing regional surge risk, checking physical fit, aligning with standards, and accounting for your specific application. We don’t just sell components—we provide a complete solution that ensures your switchgear is protected for years to come. If you’re planning a project and want to avoid the costly mistakes I’ve seen over the years, reach out to our team to discuss your surge arrester needs today. We’ll provide a tailored recommendation, no pressure, no jargon, just practical advice to keep your power infrastructure safe.

References

  1. ANSI/IEEE C62.11, Standard for Metal-Oxide Surge Arresters for Alternating Current Power Circuits (>1 kV)
  2. IEC 60099-4, Surge Arresters - Part 4: Metal Oxide Surge Arresters Without Gaps for AC Systems
  3. CSA C22.2 No. 19, Surge Arresters
  4. KYN28A-12 Medium Voltage Switchgear Technical Datasheet, ABB Group (2024)
  5. Power System Surge Protection Guide, International Council on Large Electric Systems (CIGRE) Working Group C4.411